Messtechnik • Protokollanalyse • Datenanalyse
 
P R O D U K T E
Analyser & Tester
RS232 / Fieldbus / Ethernet
Serialtest Async
Ethertest
NetDecoder
PN1 Kabeltester
ProfiTAP
Bluetooth
FTS4BT
ZigBee
MeshDecoder
USB
FTS4USB
Wireless LAN
OmniPeek Workgroup
CAN-Bus
CBT2 - Busphysik
Profibus
ProfiTrace 2 - Kombi-Analyser
ProfiCaptain 2 - DP Master
BT200 - Kabeltester
PBT3 - Busphysik
Repeater - Profibus DP
EasyConn - Diagnosestecker
T1 - Abschlusswiderstand
HandyScope on USB
HS805 - 1 GHz
HP3 - 100 MHz
HS3 - 100 MHz
HS4 - 50 MHz
Flash-Speicher-programmierung
FLASHit
Interfaces und Konverter
 
S E R V I C E
Unterlagen anfordern
email: info@brandt-data.de

NetDecoder  -  Protokollanalyser für Serial, Fieldbus & Ethernet

Frontline Test Equipment
 
NetDecoder Home | Features | Spezifikationen | Datenblatt

NetDecoder Features Summary

Included Protocol Decoders
 

Serial Protocols

  • Modbus RTU
  • Modbus ASCII
  • DNP3 over serial
  • DF1/PCCC
  • BSAP

Industrial Ethernet Protocols

  • Modbus/TCP
  • ProfiNet
  • EtherNet/IP (CIP and PCCC)
  • DNP3 over Ethernet
  • Allen-Bradley’s CSP/PCCC
  • CC-Link over Ethernet

Fieldbus Protocols

  • Allen-Bradley Data Highway Plus
  • Allen-Bradley DH-485
  • DeviceNet
  • ControlNet

Apart from the above list, NetDecoder also includes decoders for these protocols:

  • TCP, UDP, IPV4, IPV6, ARP, RARP, DNS, HTTP, VoIP-SIP, ICMP, IGMP, NBDS, NBNS, NBSS, SMTP, IBM, NetBIOS, SMB, Novell Netware (IPX, SPX, IPX NetBIOS, IPX RIP, IPX SAP, NCP), ISO, and CLNP.

DecoderScript

  • Easy-to-use scripting language to write custom decodes for proprietary protocols and/or extensions to existing protocol decoders.

Data Capture Options

  • Supports serial data capture up to 921.6K bps.
  • Serial data capture requires Frontline's RS-232 ComProbe II or RS-422/485 ComProbe.
  • The serial ComProbes connect to the PC via USB ports. · Data Highway Plus (DH+) data capture requires DHM-3500 hardware.
  • DH-485 data capture requires RS-485 serial card.
  • DeviceNet data capture requires SST's DeviceNet interface cards or RA's 1784-U2DN.
  • CAN 2.0A data capture requires SST's DeviceNet interface cards.
  • ControlNet data capture requires RA's 1784-PCC or 1784-U2CN.
  • Captured data includes data bytes, control signals, and error conditions.
  • Capture data to a single file or a series of files.

Display Windows

  • Data can be analyzed in real-time using the Event Display , Frame Display , Protocol Navigator ,
    Signal Display , Breakout Box , and Statistics , Network View , Dashboard View .
  • Simultaneously view multiple synchronized windows.
  • Real-time breakout box includes timing diagrams and counters for control signals.
  • Timing diagrams enable captured control signal transitions to be viewed with respect to captured data bytes.

Data Display Characteristics

  • Frame/Packet contents are decoded to the byte and bit level.
  • Characters can be displayed in ASCII, EBCDIC, or Baudot.
  • Nonprintable characters are displayed using hex and mnemonics.
  • Supported radices include hex, octal, decimal and binary.
  • Decoded data formats supported include 16 bit Integers, 32 bit Integers, IEEE 32 bit Floating Point, 32 bit Reverse Floating Point, and ASCII.

Display Filters

  • Display filter parameters include filter-in or filter-out protocols, messages, data patterns, and advanced mode for complex filters.
  • Quick filters for the Frame Display and Protocol Navigator windows include protocol filtering in and out, filtering on the summary pane, and filtering on messages.
  • Tab filters in the Frame Display allow you to filter in frames that contain a specific protocol layer.

Capture Filters

  • Ethernet, ControlNet and DeviceNet analyzers in NetDecoder support capture filters.
  • DeviceNet capture filters are defined on the CAN ID values.
  • ControlNet capture filters are defined on the frame MAC ID, Producer/consumer MAC ID, Frame Type (Scheduled, Unscheduled or Moderator) and Frame status (Good, Bad, Null).
  • Ethernet capture filters are defined on node pairs, MAC or IP addresses, protocol type, and message type or data pattern.

Start and Stop Triggers

  • The ControlNet analyzer using RA's 1784-PCC card supports start and stop triggers.
  • The DeviceNet analyzer using RA's 1784-U2DN and SST's interface cards support triggers.

Data Export

  • Export Events or Frames into text or binary format.
  • Exports the contents of the Frame Display's Summary Pane into CSV format.
  • Export output is suitable for importing into a spreadsheet, database or other post-process program for intricate data and protocol analysis.
  • Print the Summary Pane and/or Decode Pane information.

Network Statistics

  • Shows amount of data on the network (number of characters/bytes/events/frames/messages).
  • Displays error information.
  • Provides information on data rates (characters per second, frames per second).
  • Provides network utilization information.
  • For serial networks, it provides statistics for both the DTE/Master/Host and DCE/Slave/RTU ends.
  • Provides current, peak and average values for all network statistics metrics.

Timestamps

  • Provides both absolute and relative displays of event timing for bytes and frames/messages.
  • Calculates time intervals between bytes and between frames/messages (delta time).
  • Timestamp resolution is 100 nanoseconds.

Search

  • Search at the byte or frame level.
  • Find data by timestamps.
  • Locate errors.
  • Discover specific data patterns (patterns include wildcard characters at the bit level, nibble level, and byte level).
  • Search decoded text, with or without wildcards.

Data Transmission

  • Includes special Transmit program to send data over Ethernet cards and Serial ports.
  • The Ethernet transmit program uses the PC's NIC card.
  • The Serial transmit program requires a serial port on the PC.
  • The program can transmit data strings and files one time, multiple times, or continuously.
  • Data transmission delays can be inserted in millisecond, second, or minute increments.
  • The serial control signals can be set on or off.

Collaboration Features

  • Add notes to your capture files describing the contents of the data. Use the notes for archiving network information, or to resolve problems and sharing information between people.
  • Add bookmarks to highlight important bytes and frames for easy access. Use these bookmarks to share information and capture files between team members.
  • I/O configurations, protocol stacks, and filters can be saved for future use.

Help & Documentation

  • Comprehensive product help provides operating instructions.
  • Quick Start Guide enables rapid product set-up and operation.
  • Manuals to provide additional technology specific information.
  • Documentation is installed with the product and is also available online.